Product manual
Specifications
9
Power Specifications
The following table lists the power specifications for the internal Scorpion 40 drives.
Specification +12 VDC supply +5 VDC supply
Voltage Tolerance + or – 10% + or – 7%
Operational Current 250 milliamps max 1.35 Amps max
Standby Current 15 milliamps max 1.2 Amps max
Surge (peak) 600 milliamps max 1.5 Amps max
Ripple (peak-to-peak)
≤
100 mV
≤
100 mV
Total power consumption for the Scorpion 40 (including both the +5V and +12V
power supplies) is as follows:
Standby Power 6.0 Watts max
Operating Power 9.0 Watts typical, 10.0 Watts max
Surge (start up) 14.0 Watts max
Note: Surge power and current are measured over a 20-msec period.
The following table lists pin assignments of the power connector for the internal
Scorpion 40.
Pin Assignment
1 +12 VDC
2 +12 return
3 +5 return
4 +5 VDC
The external drives have a built-in power supply that senses the incoming voltage
and automatically adapts to voltages within the range of 100 to 240 volts, 50 to 60
Hz. The following table lists its power specifications.
Specification AC Input Voltage
100 (Japan) 120 (US) 240 (European)
AC Input Current 100 milliamps 85 milliamps 170 milliamps
AC Input Power 10.0 watts 10.0 watts 10.0 watts
Note: The drive employs a power sensing circuit that automatically detects a loss
of supply voltage from the host. Temporary loss of supply voltage or voltage
spikes may result in the drive electronics being reset to their initialized state,
but shall under no circumstances result in a loss of recorded data.