Datasheet
Table Of Contents
- 1.0 Seagate Technology support services
- 2.0 Scope
- 3.0 Applicable standards and reference documentation
- 4.0 General description
- 5.0 Performance characteristics
- 6.0 Reliability specifications
- 7.0 Physical/electrical specifications
- 8.0 About FIPS
- 9.0 About self-encrypting drives
- 10.0 Defect and error management
- 11.0 Installation
- 12.0 Interface requirements

52 Constellation.2 SAS Product Manual, Rev. G
12.0 Interface requirements
This section partially describes the interface requirements as implemented on Constellation.2 drives. Addi-
tional information is provided in the SAS Interface Manual (part number 100293071).
12.1 SAS features
This section lists the SAS-specific features supported by Constellation.2 drives.
12.1.1 task management functions
Table 5 lists the SAS task management functions supported.
12.1.2 task management responses
Table 6 lists the SAS response codes returned for task management functions supported.
Table 5: SAS task management functions supported
Task name Supported
Abort Task Yes
Clear ACA Yes
Clear task set Yes
Abort task set Yes
Logical Unit Reset Yes
Query Task Yes
Table 6: Task management response codes
Function name Response code
Function complete 00
Invalid frame 02
Function not supported 04
Function failed 05
Function succeeded 08
Invalid logical unit 09