Specifications

5-2 Sun StorEdge A1000 and A3x00/A3500FC Best Practices Guide November 2002
5.1 Verifying FRU Functionality
This section contains the following topics:
Section 5.1.1, “Disk Drives” on page 5-3
Section 5.1.2, “Disk Tray” on page 5-4
Section 5.1.3, “Power Sequencer” on page 5-5
Section 5.1.4, “SCSI Cables” on page 5-6
Section 5.1.5, “SCSI ID Jumper Settings” on page 5-7
Section 5.1.6, “SCSI Termination Power Jumpers” on page 5-7
Section 5.1.7, “LED Indicators” on page 5-7
Section 5.1.8, “Backplane Assembly” on page 5-7
Section 5.1.9, “D1000 FRUs” on page 5-7
Section 5.1.10, “Verifying the HBA” on page 5-8
Section 5.1.11, “Verifying the Controller Boards and Paths to the A3x00/A3500FC”
on page 5-8
Section 5.1.12, “Controller Board LEDs” on page 5-9
Section 5.1.13, “Ethernet Port” on page 5-10
The troubleshooting and replacement procedures for the following controller
module FRUs are documented in detail in the Sun StorEdge A3500/A3500FC
Controller Module Guide:
Battery Canister F370-2434
Controller Fan F370-2433
DC Power and Battery Harnesses F565-1397
Power Supply F370-2436
Power Supply Fan F370-2432
Power Supply Housing F370-2869
Mounting Rail 370-3655
Note If a fan failure message appears in the rmlog.log, replace the fan FRU that
was reported to have failed (controller or power supply fan) even if the fan appears
to be spinning. The fan circuitry has an RPM sensor which triggers the fan failure
message. The fan may continue to spin but in a degraded mode (at half speed).