Specifications

Chapter 3 RAID Manager Installation and Configuration 3-5
3.1.6 Maximum LUN Support
The default setting for maximum LUN support is 8. If more than 8 LUNs are
required on each A3x00, refer to "Maximum LUN Support..." in the RAID Manager 6
Release Notes for details. Also see FIN I0589 for PCI HBAs.
Note When performing a RAID Manager upgrade, if extended LUN support is
enabled, ensure that you reenable it during the upgrade as described in the Upgrade
Guide.
Caution Do not use the add16lun.sh script found on the RAID Manager 6.1.1
CD-ROM on a PCI machine. Details are available in FIN I0589.
3.2 LUN Creation/RAID Level
This section contains the following topics:
Section 3.2.1, “General Information” on page 3-5
Section 3.2.2, “LUN Numbers” on page 3-6
Section 3.2.3, “The Use of RAID Levels” on page 3-6
Section 3.2.4, “Cache Mirroring” on page 3-6
Section 3.2.5, “Reconstruction Rate” on page 3-7
Section 3.2.6, “Creation Process (Serial/Parallel) Time” on page 3-8
Section 3.2.7, “DacStor Size (Upgrades)” on page 3-8
3.2.1 General Information
RAID Manager 6.22x has an "immediate LUN availability" feature: a LUN
becomes Optimal in a few minutes, while the rest of the initialization is being
processed in the background. See Section 3.2.6, “Creation Process (Serial/Parallel)
Time” on page 3-8.
If LUN creation is scripted, see Section 3.2.6, “Creation Process (Serial/Parallel)
Time” on page 3-8.
For multi-initiator configurations, see Section 3.3, “LUN Deletion and
Modification” on page 3-9.