Specifications

Chapter 1 Troubleshooting Overview 1-11
I0828 05/21/02 RM 6.22.1 LUNs may become inaccessible after upgrading from RM
6.22 to 6.22.1 or after adding unformatted disk drives to
RM 6.22.1.
I0845 06/25/02 RAID Manager 6 RAID Manager 6 may hang for 3-8 minutes when an IBM
drive is in the failed state in a Sun StorEdge
A1000/A3x00/A3500FC array.
I0860 08/02/02 RAID Manager 6 with
Solaris 9
RAID Manager 6.22.1 with A1000/A3x00/A3500FC
arrays needs a new patch revision for Solaris 9.
I0865 TBD Sun StorEdge A3500FC
Arrays
Extraneous physical device paths may appear.
TABLE 1-6 FCOs Affecting the Sun StorEdge RSM 2000/A3x00/A3500FC Product Family
FCO
Number
Release
Date Product Description
A0120 02/27/98 RSM Array 2000 WD2S
Card
Power glitch may cause disks to go off-line on RSM
Array 2000 configured without an uninterruptable power
supply (UPS).
A0162 03/09/00 Power Supply
A1000/D1000
Sun StorEdge A1000 and D1000 power supplies fail with
amber LED.
A0163 03/31/00 UDWIS Sbus host adapter
A1000/D1000,
A3x00/A3500
Systems with large quantities of UDWIS/Sbus host
adapters installed may not come up after reboot due to
miscommunication between the SCSI host and the target.
A0164 05/12/00 FC100/P card,
A5x00/A3500
Systems with FC100/P cards (375-0040-xx) having Molex
optical transceivers, may cause increasing numbers of
loop errors, excessive LIPs, and SCSI parity errors as they
age.
A0165 06/19/00 RSM 2000 A3000 battery
backup unit
Any battery backup unit over two years old may not
have enough energy to hold data in the RSM 2000 or
A3000 controller’s write-back cache for 72 hours in the
event of a power outage.
TABLE 1-5 FINs Affecting the Sun StorEdge A1000 and RSM 2000/A3x00/A3500FC Product Family
FIN
Number
Release