Specifications
Chapter 1 Troubleshooting Overview 1-9
I0589 06/21/00 Any RM 6 version glm.conf file must be modified to support more than 8
LUNs on any PCI-SCSI connected A1000 or A3x00 using
any version of RM 6.
I0590 07/20/00 Sun StorEdge A3500FC
upgrade kit
The SCSI NVSRAM will overwrite the FC controller
NVSRAM if following the documented A3500 SCSI to FC
upgrade procedure.
I0594 I0594 Sun StorEdge A3x00 and
A3500 arrays.
Some StorEdge A3500 products shipped with the
StorEdge A3000 name tag lead customers to believe the
wrong product was delivered.
I0612 09/08/00 Sun StorEdge Array
Configuration
RM6 may detect a non-existent 2MB dacstore on factory
formatted hard disk drives.
I0613 09/20/00 Sun StorEdge A1000 array When replacing a failed controller board on the A1000, it
is important to first verify the version of RAID Manager
software, the controller firmware level and controller
memory size.
I0619 10/12/00 Sun StorEdge A1000 and
A3x00 Arrays
Proper procedures for booting from the Sun StorEdge
A1000 or A3x00 hardware RAID devices, including
known issues and problems.
I0634 11/30/00 Sun StorEdge A3x00 Array
controller failover
Sun StorEdge A3x00 Array controller failover may cause
temporary delay in processing of pending disk I/O.
I0637 01/10/01 Sun StorEdge A3500 Array A3500 controller powering up prior to Dilbert trays due
to wrong connections of L5, R5,L6, and R6 power
sequencer cables.
I0643 01/10/01 Sun StorEdge A3x00 with
RAID Manager
Sun StorEdge A3x00 array configurations with RAID
Manager 6.1.x may be susceptible to controller
“deadlocks”.
I0648 02/16/01 Sun StorEdge A3x00 Array Disks in Sun StorEdge A3x00 arrays might go offline,
making the devices unavailable.
I0653 05/08/01 RSM 2000 array shelves RSM array shelves may collapse under weights greater
than 40 lbs. (18.2 kg), causing system damage or personal
injury.
I0670 06/15/01 Sun StorEdge D1000 ESM
board and Sun StorEdge
A3x00/A3500FC arrays
Procedure to replace the D1000 Environmental Service
Module (ESM) board in A3x00/A3500FC arrays.
I0684 06/21/01 RAID Manager 6.22
healthchk utility
RAID Manager 6.22 healthchk utility might not report
power supply or fan failures in Sun StorEdge A3x00
arrays, which might result in loss of availability.
TABLE 1-5 FINs Affecting the Sun StorEdge A1000 and RSM 2000/A3x00/A3500FC Product Family
FIN
Number
Release
Date Product Description