Specifications
1-8 Sun StorEdge A1000 and A3x00/A3500FC Best Practices Guide • November 2002
I0511 07/28/99 VM DMP interferes with
A3x00 RDAC
Enabling DMP with RDAC on A3x00 and A1000 may
cause private regions to be lost.
I0520 04/24/01 Quorum device in Sun
Cluster
Servicing storage that contains a device that is used as a
quorum device in a Sun Cluster environment.
I0531 01/07/00 A3500FC parallel LUN
modifications
UPDATED FIN. Sun StorEdge A3500FC with
preconfigured LUNs may encounter errors if parallel
LUN modifications are made using Sbus host adapters.
I0536 09/09/00 E10000 with A3x00 DR E10000 systems with an A3x00 attached may encounter
DR errors.
I0594 09/08/00 Sun StorEdge A3000 name
plate
A3000 name tag was applied on the product instead of
Sun StorEdge A3500 causes confusion to the customers.
I0547 01/21/00 UDWIS fcode Intermittently, SCSI devices connected to a UDWIS card
may not be usable after a reboot.
I0551 02/08/00 Large Sun StorEdge
A1000, A3000, A3500
configurations
Boot process and controller on-line process may take
hours in systems with large Sun StorEdge A1000, A3000,
A3500, or configurations.
I0552 01/24/00 isp driver bug SCSI devices (especially in a multi-hosted configuration)
may go off-line after isp errors.
I0553 02/04/00 A3x00 controller firmware The firmware download procedure documented in
A3x00 Controller Replacement Guide may render the
controller unusable.
I0557 05/23/00 RM 6.1.1 firmware Differences in LUN capacity after firmware upgrade on
Sun StorEdge A3000 or RSM 2000 hardware RAID
controllers.
I0566 06/12/00 Solaris 8 with any Sun
StorEdge A3x00/A1000
A patchID 108553-xx is required to run Solaris 8 with RM
6.22.
I0569 03/31/00 isp fcode 1.28 probe error UDWIS Sbus host adapter with isp-fcode 1.28 can cause
“invalid command” during probe-scsi-all or boot -hv
from a Sun StorEdge D1000.
I0573 09/28/00 Storage Array A1000,
A3x00
Sun StorEdge A1000, A3000, A3500, or A3500FC requires
the existence of LUN 0 for proper operation.
I0579 06/07/00 UDWIS/Sbus SCSI
adapter
Systems with Ultra DWIS/Sbus host adapter slow to a
halt under heavy I/O loads and the console displays
“SCSI transport failed” error messages.
I0586 06/22/00 Sun StorEdge A3500FC
connectivity
The hardware and software requirement to use the
onboard SOC+ the I/O boards to connect the A3500FC.
TABLE 1-5 FINs Affecting the Sun StorEdge A1000 and RSM 2000/A3x00/A3500FC Product Family
FIN
Number
Release
Date Product Description