Specifications

Chapter 1 Troubleshooting Overview 1-7
Tables 1-5 and 1-6 list the current FINs and FCOs affecting the Sun StorEdge RSM
2000/A3x00/A3500FC product family as of January 2001.
TABLE 1-5 FINs Affecting the Sun StorEdge A1000 and RSM 2000/A3x00/A3500FC Product Family
FIN
Number
Release
Date Product Description
I0310 07/09/97 SSA RSM 21x RSM Array
2000
Updated - Failure to follow documented installation
procedures to remove shipping brackets and reseat
drives may cause multiple disk errors.
I0312 08/31/00 RSM Array 2000 patches Required set of patches for the Sun RAID Storage
manager Array 2000.
I0324 05/06/97 Sun VTS, RSM Array 2000 Problem with Sun VTS not probing LUNs located on an
RSM Array 2000 system.
I0325 06/09/97 RSM Array 2000, Power
sequencer
Power in the RSM Array 2000 will be on when the
keyswitch if off and one of the power sequencer’s circuit
breaker is off.
I0328 06/13/97 RSM Array 2000 disk
configuration
Some RSM 2000’s installed with 9.0 GB disk drives were
configured as if they only had 4.0 GB disk drives
attached.
I0332 06/20/97 SSA 21x, RSM Array 2000 INFORMATIONAL ONLY! Disk LEDs light or blink in
an inconsistent manner during power up on some disk
trays.
I0334 07/09/97 SSA RSM Model 219, RSM
Array 2000 Seagate
ST19171WC 9.0 GB disk
drive
“Cushioning damper” kit for Seagate ST19171WC 9.0 GB
disk drives installed in a SPARCstorage Array RAID
Storage Manager Model.
I0362 12/18/98 RSM Array 2000 RM 6.1 UPDATED FIN. Updated parity error recovery
procedure.
I0368 04/10/98 RSM Array 2000 controller
board
UPDATED FIN. Memory error detection on the RSM
Array 2000 controller logic board is ineffective.
I0440 10/29/98 RM Rev 6.1.1 RM 6.1.1 with Sun StorEdge A1000, A3000, or A3500 may
experience status check problems.
I0441 10/30/98 Sun StorEdge D1000 disk
tray
New disk firmware revision 7063 for ISP boot failures on
D1000’s with Seagate ST39173WC 9 Gbyte disks.
I0473 03/09/99 Solaris 7, RM6.1.1 UG
A3x00/A1000
Solaris 7 upgrade recommendations for Sun StorEdge
A3x00/A1000.
I0505 08/09/99 RM 6.1.1 RAID LUN
recovery
UPDATED FIN. A3x00/A1000 RAID 0 LUN recovery
requires stopping I/O to the LUN.
I0509 06/30/99 RM 6 and Solaris kernel
corruption
RAID Manager large rdriver.conf files need a patch to
prevent panic.