Specifications

Chapter 1 Troubleshooting Overview 1-3
1.2 Available Tools and Information
This section contains the following topics:
Section 1.2.1, “Documentation” on page 1-3
Section 1.2.2, “Web Sites” on page 1-4
Section 1.2.3, “Internal Directory” on page 1-4
Section 1.2.4, “Obtaining the Latest Version of RAID Manager” on page 1-4
Section 1.2.5, “RAID Manager 6.0, 6.1 and 6.22 Are not Supported” on page 1-5
Section 1.2.6, “Serial Cable” on page 1-5
Section 1.2.7, “RAID Manager 6.xx Architecture White Paper Available” on
page 1-6
1.2.1 Documentation
The current documentation set is listed in “Related Documentation” on page -xvi.
The documentation set is also available on the following web sites:
http://edist.central
http://infoserver.central/data/syshbk
5 Do not perform boot -r while a controller is held in reset. See Section 6.1,
“Controller Held in Reset, Causes, and How to Recover” on page 6-2.
6 Do not enable 16/32 LUN support unless it is necessary (refer to FIN I0589).
7 Do not run A3x00s in a production environment without a LUN 0.
8 Do not move disk drives between hardware arrays (A1000, RSM2000, A3x00, and
A3500FC) or in the same array.
9 Do not enable DMP on VxVM pre-3.0.2 releases; RAID Manager 6.22x/DMP
compatibility issue has been resolved in VxVM 3.0.2. Refer to the VxVM
documentation for details.
10 Do not revive a disk drive if it has been failed by a controller.
TABLE 1-2 A3x00/A3500FC Commandments - Thou Shalt Not (Continued)
Number Commandment