Specifications
A-6 Sun StorEdge A1000 and A3x00/A3500FC Best Practices Guide • November 2002
The following table provides power consumption information for a given array
system configuration (minimum and maximum). The difference in power
consumption at 30˚C and 40˚C is due to the cooling fans spinning at a higher speed
at 40˚C.
TABLE A-5 Power Consumption Specifications
Configuration
Power Consumption
at 30˚C
(BTU/Watts)
Power Consumption
at 40˚C
(BTU/Watts)
A3500 Liteusing 9-GB or 18-GB disk
drives (minimum configuration)
1602/469 1803/528
A3500 Liteusing 9-GB or 18-GB disk
drives (maximum configuration)
2847/834 3048/893
1x5 using 9-GB disk drives
(minimum configuration)
2131/624 2634/772
1x5 using 9-GB disk drives
(maximum configuration)
6021/1764 6524/1912
1x5 using 18-GB or 36-GB (1”) disk
drives (minimum configuration)
2206/646 2709/794
1x5 using 18-GB or 36-GB (1”) disk
drives (maximum configuration)
6472/1896 6975/2044
1x5 using 36-GB (1.6”) disk drives
(minimum configuration)
2476/725 2979/873
1x5 using 36-GB (1.6”) disk drives
(maximum configuration)
5845/1712 6348/1860
2x7 using 9-GB disk drives
(minimum configuration)
3889/1139 4593/1345
2x7 using 9-GB disk drives
(maximum configuration)
8868/2598 9572/2804
2x7 using 18-GB or 36-GB (1”) disk
drives (minimum configuration)
4039/1183 4744/1390
2x7 using 18-GB or 36-GB (1”) disk
drives (maximum configuration)
9500/2783 10204/2990
2x7 using 36-GB (1.6”) disk drives
(minimum configuration)
4579/1341 5283/1548
2x7 using 36-GB (1.6”) disk drives
(maximum configuration)
8621/2526 9324/2732
3x15 using 9-GB disk drives
(minimum configuration)
6393/1873 7902/2315