Specifications
6-10 Sun StorEdge A1000 and A3x00/A3500FC Best Practices Guide • November 2002
1. From the Configuration screen, select a module from RAID Module.
When the LUN was deleted, all the drives assigned to that LUN should have been
moved to the Unassigned drive area under module information.
2. Highlight the Unassigned drive icon.
Right click the Unassigned icon and select Create LUN...
3. Select the appropriate input for the RAID Level, Number of Drives, and Number
of LUNs options.
Create an exact replica from the module profile. As you select drives under Number
of Drives, select the drives in the exact order as before the loss of the LUN.
4. Click Options and select the segment size and the caching parameters
When you are finished, click OK. The “Create LUN” screen appears.
5. Click Create.
Creating the LUN takes a few minutes. The Configuration screen indicates the RAID
Manager is formatting the LUN and then indicates the LUN is optimal.
6. After the LUN becomes optimal, exit RAID Manager 6 and shut down the host.
7. Power cycle the controllers.
8. Bring up the Host.
The LUN should be in its original state.
9. Restart RAID Manager and verify the LUN is created.
6.3.5 Disabling the Debug Options
After you create the LUN, perform these steps from the serial port using the
VKI_EDIT_OPTIONS on both controllers to disable the Debug Options.
1. At the RAID controller shell prompt, enter:
2. To clear the settings, type:
Press Return or Enter.
->
VKI_EDIT_OPTIONS
c