Technical information
2. Determine the hardware path of the flash card to be removed (0/2/0/0.0 or 0/3/0/0.0).
The information in the State and Status fields of the display will show information on the
failed flash card.
2.7.1.6 Verifying Flash Card Replacement
1. To verify proper operation of the flash card, enter the following command:
/sbin/ftsmaint ls hw_path
where hw_path is the hardware path of the flash card (
0/2/0/0.0 or 0/3/0/0.0).
2. Check the State and Status fields. The State field should be listed as CLAIMED
and the Status field should be listed as Online.
3. To write the current version of the /stand directory to the new flash card, refer to
Section 2.7.2.2.
2.7.1.7 Preparing to Remove a Disk Drive
Verify the location and status of the disk drive using the following procedure.
1. Determine the hardware path and path name of the disk to be replaced. Refer to Section 2.6.4 for
a complete listing of the hardware paths and device names of the disk drives.
2. Check the state of the disk drive to be replaced by entering the following command:
/sbin/ftsmaint ls hw_path
where where hw_path is the hardware path of the disk drive to be replaced.
If the disk is being replaced because of a disk failure (State field is listed as ERROR) go to
Step 6. Otherwise, continue with Step 3.
3. Check to see if the disk being replaced is an online, mirrored physical volume (also called
an LVM disk drive), or an online, non-mirrored LVM disk drive by using the following
command:
/sbin/vgdisplay -v
The display is shown in the following format.
Sample Screen (partial):
11.00.01 Operating and Maintenance Procedures
file:///H|/CSDoc/leotsg/section2.html (18 of 30) [01/12/2000 11:50:32 AM]