Specifications

Key to power-on and reset timing data
Label Time
TM
25 µsec
TN 400 nsec*
TP 1 msec*
TQ 30 seconds*
TR 450 msec for master drive*
TR 400 msec for slave drive*
TS 30.5 seconds*
Note. All timings indicate minimum times except for those marked with
an asterisk (*), which show
maximum
allowable times.
RESET–
BSY
DASP–
Control
Registers
Notes:
1. Drive 0 can set BSY=0 if Drive 1 is not present
2. Drive 0 can use DASP– to indicate it is active if Drive 1 is not present
3. DASP– can be asserted to indicate that the drive is active
BSY
PDIAG
DASP–
Control
Registers
Drive 1
Drive 0
(1)
(2)
TS
TQ
TR
TP
TM
TN
(3)
(3)
Figure 16. System power-on and reset timing
70 ATA Interface Reference Manual, Rev. C