Datasheet
Medalist Pro Product Manual, Rev. D 83
37 00 Rounded parameter error N
39 00 Saved parameters not supported Y
3D 00 Identify message with invalid bits N
3F 00 Target operation command changed N
3F 01 Microcode changed Y
3F 02 SCSI-1/SCSI-2 change N
40 00 Target operating conditions have changed Y
40 01 DRAM parity error detected Y
40 93 Error in write to flash Y
42 00 Power on or self test error N
43 00 Message reject error Y
44 00 Internal controller error N
45 00 Selection or reselection error N
47 00 Bus parity error Y
48 00 Initiator detected error Y
49 00 Initiator received invalid message from drive Y
4E 00 Drive attempted overlapped commands Y
5B 00 Log exception—factory option N
5B 01 Threshold condition met—factory option Y
5B 02 Log counter reached maximum value—factory option N
5B 03 Log list codes all used—factory option N
5C 00 RPL status change, drive lost synchronization N
80 00 General firmware error qualifier N
Sense
key Description Supported