Datasheet
Medalist Pro Product Manual, Rev. D 65
Table 16: Model “N,” single ended I/O, 50 conductor, signal/contact assignments
Note. The minus sign next to the signal indicates asserted state is the low voltage of the two levels used for
logic signals.
*CAUTION: Connector contact 25 must not be connected to ground at the host end of the cable. If the I/O
cable should accidently be plugged in upside down, terminator power on pin 26 will be shorted to
ground.
Notes [ ]: See page following Table 20.
Signal
name [1]
Connector
contact
number [3]
Cable
conductor
number [11]
Connector
contact
number [11]
Signal
name [1]
GND 1 1 2 2 –DB0
GND 3 3 4 4 –DB1
GND 5 5 6 6 –DB2
GND 7 7 8 8 –DB3
GND 9 9 10 10 –DB4
GND11111212–DB5
GND13131414–DB6
GND15151616–DB7
GND17171818–DBP
GND19192020GND
GND21212222GND
GND23232424GND
NC [10] 25* 25 26 26 TERMPWR
GND27272828GND
GND29293030GND
GND31313232–ATN
GND33333434GND
GND35353636–BSY
GND37373838–ACK
GND39394040–RST
GND41414242–MSG
GND43434444–SEL
GND45454646–C/D
GND47474848–REQ
GND49495050–I/O