Technical data

41
Digit Meaning
6: Peripheral Drives 0: No CD-ROM drive and no floppy disk drive
1: Floppy disk drive and no CD-ROM drive
2: Combo drive and no CD-ROM drive
3: CD-ROM drive and floppy disk drive
4: CD-ROM and combo drive
7: Disk Drives 0: No hard disk drive
3: 2 GB
4: 4 GB
7: 2 GB w/4 GB AV drive (StudioZ)
9: 9 GB
L: 4 GB w/4 GB AV drive (StudioZ)
8: Operating System 0: No operating system
1: DOS/Windows
2: Windows NT Workstation
3: Windows 95
4: Windows NT Server, phase III
7: Windows NT Server, phase II
9: Solaris
A: Windows NT Workstation/Solaris
9: Revision Variable
Specifications
Base Unit Dimension (HxWxD) Base Unit Weight Maintenance Clearance
8.75 x 16.65 x 25.25 inches
(22.2 cm x 42.3 cm x 64.1 cm)
without rails, handles, and cables
64 lb (140.8 kg)
without rails
36 inches (91.4 cm)
front and back
Electrical
Power Consumption
AC line
voltage:
Frequency: Phase: Rated receptacle
current:
539 Watts (based on
120 VAC, 60 Hz)
90-132 VAC 47-63 Hz 1-phase 15-amp, 125V
180-264 VAC 47-63 Hz 1-phase 15-amp, 250V
Environmental Recommendations
Environmental Impact
Ambient room temperature, operating:
50
°
to 80
°
F (10
°
to 26
°
C)
Heat Dissipation:
1878 BTUs/hour (7.88 kcals/min)
Relative Humidity, operating:
20 to 80% (non-condensing)