User manual
iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
143
failure
ERROR IPC FW
upgrade
timeout
System firmware upgrade timeout on another
controller
INFO Config
imported
<string> config imported
HAC events
Level Type Description
INFO RG owner
changed
The preferred owner of RG <name> has been
changed to controller <number>.
INFO Force CTR
write through
Controller <number> forced to adopt write-
through mode on failover.
INFO Restore CTR
cache mode
Controller <number> restored to previous
caching mode on failback.
INFO Failover
complete
All volumes in controller <number> completed
failover process.
INFO Failback
complete
All volumes in controller <number> completed
failback process.
INFO CTR inserted Controller <number> is inserted into system
ERROR CTR removed Controller <number> is removed from system
ERROR CTR timeout Controller <number> gets no response
ERROR CTR lockdown Controller <number> is locked down
ERROR CTR memory
NG
Memory size mismatch
ERROR CTR firmware
NG
Firmware version mismatch
ERROR CTR lowspeed
NG
Low speed inter link is down
ERROR CTR
highspeed NG
High speed inter link is down
ERROR CTR backend
NG
SAS expander is down
ERROR CTR frontend
NG
FC IO controller is down
INFO CTR reboot
FW sync
Controller reboot, reason [Firmware
synchronization completed]
Clone events
Level Type Description
INFO VD clone
started
VD <name> starts cloning process.
INFO VD clone
finished
VD <name> finished cloning process.
WARNING VD clone
failed
The cloning in VD <name> failed.
INFO VD clone
aborted
The cloning in VD <name> was aborted.
INFO VD clone set The clone of VD <name> has been designated.
INFO VD clone reset
The clone of VD <name> is no longer
designated.