Chapter 7 Troubleshooting
7.1 System Buzzer
The system buzzer features are listed below:
1. The system buzzer alarms 1 second when system boots up successfully.
2. The system buzzer alarms continuously when there is error occurred. The alarm will
be stopped after error resolved or be muted.
3. The alarm will be muted automatically when the error is resolved. E.g., when RAID
5 is degraded and alarm rings immediately, user changes / adds one physical disk
for rebuilding. When the rebuilding is done, the alarm will be muted automatically.
7.2 Event Notifications
PD events
Level Type Description
INFO PD inserted Disk <slot> is inserted into system
WARNING PD removed Disk <slot> is removed from system
ERROR HDD read
error
Disk <slot> read block error
ERROR HDD write
error
Disk <slot> write block error
ERROR HDD error Disk <slot> is disabled
ERROR HDD IO
timeout
Disk <slot> gets no response
INFO PD upgrade
started
PD [<string>] starts upgrading firmware
process.
INFO PD upgrade
finished
PD [<string>] finished upgrading firmware
process.
WARNING PD upgrade
failed
PD [<string>] upgrade firmware failed.
HW events
Level Type Description
WARNING ECC single Single-bit ECC error is detected at <address>
ERROR ECC multiple Multi-bit ECC error is detected at <address>
INFO ECC dimm ECC memory is installed
INFO ECC none Non-ECC memory is installed
INFO SCSI bus
reset
Received SCSI Bus Reset event at the SCSI
Bus <number>
ERROR SCSI host
error
SCSI Host allocation failed
ERROR SATA enable
device fail
Failed to enable the SATA pci device