User manual

iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
101
Chapter 6 Troubleshooting
6.1 System Buzzer
The system buzzer features are listed below:
1. The system buzzer alarms 1 second when system boots up successfully.
2. The system buzzer alarms continuously when there is error occurred. The alarm will
be stopped after error resolved or be muted.
3. The alarm will be muted automatically when the error is resolved. E.g., when RAID
5 is degraded and alarm rings immediately, user changes / adds one physical disk
for rebuilding. When the rebuilding is done, the alarm will be muted automatically.
6.2 Event Notifications
PD events
Level Type Description
INFO Disk inserted Disk <slot> is inserted into system.
WARNIN
G
Disk removed Disk <slot> is removed from system.
ERROR Disk read error Disk <slot> read block error
ERROR Disk write error Disk <slot> write block error
ERROR HDD failure Disk <slot> is disabled.
ERROR HDD failure Disk <slot> gets no response
HW events
Level Type Description
WARNIN
G
ECC error Single-bit ECC error is detected at <address>.
ERROR ECC error Multi-bit ECC error is detected at <address>.
INFO ECC info ECC memory is installed.
INFO ECC info Non-ECC memory is installed.
INFO SCSI info Received SCSI Bus Reset event at the SCSI
Bus <number>.
EMS events
Level Type Description
INFO Power installed Power <item> is installed.
ERROR Power absent Power <item> is absent.