Specifications

DAT DRIVE
9.2 Preventive Maintenance
3/96 Application Module
X
Service 101
Honeywell Inc.
9.2 Preventive Maintenance
DAT head cleaning
The DAT drive heads require cleaning:
after every 28 hours of actual operation.
when the “Caution” indicator status on front of the drive is displayed.
See the table above for details.
Head cleaning
procedure
The following table provides the procedure for using the DAT cleaning
cassette. This cassette is available from Honeywell logistics under the
number 51196257-200 (HP 92283K).
Table 9-2 DAT Drive Head Cleaning Procedure
Step Action
1
Insert the cleaning cassette into the drive.
2
The drive will automatically load the cassette and
clean the heads.
3
The drive will automatically eject the cassette when
the cleaning cycle is complete.
4
Update the usage count on the label of the cleaning
cassette.
5
Discard the cleaning cassette after 28 uses; it is worn
out at that point.