User guide
,VRODWLQJ)DXOWV 101
Troubleshooting
Temperature
is under limit
Critical none Critical
Temps
<9.5º C
– Room temperature is too low.
– Temperature sensor is faulty. Compare
temperature reported by peer BCC.
Major
Warning
none Non-
critical
Temps
<15.5º C
Voltage is over
limit
Critical none Critical Power supply is faulty. Check status and
correct.
Major
Warning
none Non-
critical
Voltage is
under limit
Critical none Critical Either power supply is faulty. Check status
and correct.
Major
Warning
none Non-
critical
Peer BCC
status,
temperature
and voltage
are Not
Available
Major
Warning
none Both
BCCs:
Non-
critical
Firmware on BCC A and BCC B are
different versions.
none Not
Available
Internal bus is faulty. Contact HP technical
support to replace backplane.
7DEOH 7URXEOHVKRRWLQJ7DEOHFRQWªG
Problem
Description
HW Event
Category
LED
State
STM
Status Probable Cause/Solution