Technical data

U26140-J-Z146-3-76 71
4 mm Autoloader Status and error messages
Operator Attention Required LED is steady amber
UpgradeErr The autoloader has failed to
download an upgrade of the
firmware via SCSI.
Check the SCSI connection
and try again.
Write-
Protected
Tape
A WRITE, WRITE FILEMARK
or ERASE command has
been attempted on a write-
protected tape.
Remove the tape and change
it to write-enabled.
Cannot Write
Non-MRS
Tape
A WRITE, WRITE FILEMARK
or ERASE command has
been attempted on a non-
Media Recognition System
tape.
Remove the tape and replace
with a Media Recognition
System tape.
Worn Media A high error rate has been
detected writing, suggesting
that the tape is nearing the
end of its useful life.
Replace the cartridge with a
new one.
Write Fail A WRITE, WRITE FILEMARK
or ERASE command has
failed.
Use a new cartridge.
Error message Meaning Status/action
Drive Comms
Error
Communication between the
MTC drive and changer
mechanism is disturbed.
Notify your corresponding
Service.
FRU 1 Dead The controller board for the
embedded MTC drive has
failed its self-test.
Notify your corresponding
Service.
FRU 2 Dead The embedded drive
mechanism has failed its self-
test.
Notify your corresponding
Service.
Error
message
Meaning Status/action