Product manual

4 Medalist 13640, 10230, 6422 and 3210 Product Manual, Rev. B
Wet bulb temperature
(max) 29.4°C (op.), 29.4°C (nonop.)
Altitude (meters below
mean sea level, max)
–122 to 3,048 (op.)
–122 to 12,192 (nonop.)
Shock, operating
(Gs max at 11 msec) 15
Shock, nonoperating
(Gs max at 11 msec)
(Gs max at 2 msec)
75
200
Vibration, operating 0.50 G (0 to peak, 22–350 Hz)
Vibration, nonoperating 5.0 Gs (0 to peak, 22–350 Hz)
Drive acoustics
(bels—sound power)
Idle mode
(dBA—sound pressure)
3.5 (typical), 3.9 (max)
30 (typical)
Drive acoustics
(bels—sound power)
Read/Write mode
(dBA—sound pressure)
4.0 (typical), 4.3 (max)
32 (typical)
Nonrecoverable read
errors 1 per 10
14
bits read
Mean time between
failures (power-on
hours)
400,000
Contact start-stop cycles
(25°C, 40% relative
humidity)
40,000
Service life (years) 5
Drive Specification ST313640A ST310230A ST36422A ST33210A