Product manual
If multiple log pages are sent to the data buffer, they should
be sent in ascending order by page code. If there are
multiple parameters within a page, they should be sent in
ascending order by parameter code. If the page codes are
sent out of order, the device server should return CHECK
CONDITION status. The sense key will be set to ILLEGAL
REQUEST, and the additional sense code will be set to
INVALID FIELD IN PARAMETER LIST.
3.7.1.1 Log page format
The log page format allows the initiator to specify attributes it wants to
monitor and provides additional parametric instructions that the initiator
can set for the specific attribute. Both the Log Select command and the
Log Sense command use the Log page. However, the Log Sense
command does not use all of the functions of the Log page. This section
discusses the Log page format and applies to both commands. Differ-
ences in how the Log Sense command uses log pages are discussed in
the Log Sense section.
Bytes
Bits
7654321 0
0 Reserved Page Code
1 Reserved
2–3 Page length (
n
–3)
Log Parameter Structure
4 to
x
+
3
Log Parameter (First)
(Length x bytes
)
n –
y
Log Parameter (last)
(Length
y
bytes
)
Medalist Pro 2160N/2160WC Product Manual, Rev. A 77