3.6.10 Read Long command (3E
H
)
When the drive receives the Read Long command, it transfers data to
the initiator.
Bytes
Bits
7654321 0
00011111 0
1 LUN 0000 0
2–5 Logical block address
60000000 0
7–8 Byte transfer length
90000000 0
Bytes 2–5
The
logical block address
specifies the LBA where the drive
begins reading data.
Bytes 7–8
The
byte transfer length
specifies the number of bytes
transferred to the initiator. The drive transfers the logical
block size plus twenty. If the byte transfer length is 0, the
drive does not transfer any data to the initiator. This condi-
tion is not considered an error. Otherwise, transfer length
must be 532 (214
H
) Bytes.
3.6.11 Write Long command (3F
H
)
When the drive receives the Write Long command, it writes one logical
block of data and twenty bytes of error correction code (ECC) to the disc.
During this command, the drive does not perform any ECC verification.
Bytes
Bits
7654321 0
00011111 1
1 LUN 0000 0
2–5 Logical block address
60000000 0
7–8 Byte transfer length
90000000 0
Bytes 2–5
The
logical block address
specifies the LBA where the drive
begins writing data.
74 Medalist Pro 2160N/2160WC Product Manual, Rev. A