Product manual

C.7 Control Mode page (0A
H
)
The Control Mode page is shown below. This table summarizes the
function, the default value and the changeability of each bit.
Bytes
Bits
76543 2 1 0
0 PS (1) Page code (0A
H
)
1 Page length (0A
H
)
2 Reserved RLEC
default 0 0 0 0 0 0 0 0
changeable 0 0 0 0 0 0 0 0
3
Queue
algorithm modifier
Reserved QErr DQue
default 0 0 0 1 0 0 0 0
changeable 1 1 1 1 0 0 0 1
4 EECA Reserved RAENP UAAENP EAENP
default 0 0 0 0 0 0 0 0
changeable 00
H
5 (default) Reserved (00
H
)
changeable 00
H
6–7 (default) Ready AEN hold-off period (0000
H
)
changeable 0000
H
8–9 (default) Busy timeout period (FFFF
H
)
changeable 0000
H
10–11
(default)
Reserved (0000
H
)
changeable 0000
H
Byte 2
The RLEC bit is not implemented.
Byte 3
The queue algorithm modifier field is only effective if the
disable queuing bit is zero. When bit 4 in the queue
algorithm modifier field is 1, the drive may use tagged
command queuing to change the order in which it exe-
cutes commands. When bit 4 in the queue algorithm
modifier field is 0, the drive always executes commands
according to the order sent by the initiator.
Medalist Pro 2160N/2160WC Product Manual, Rev. A 113