Product manual

All mode pages contain a 2-byte header that contains the page code and
the page length for that particular page. The header is shown below.
Bytes
Bits
7 6 543210
0 PS Page code
changeable 1 0 0 0 0000
1 Page length
changeable 00
H
Byte 0
During the Mode Sense command, the
PS
(parameter savable)
bit is 1, which means the mode page is saved on the disc. During
the Mode Select command, you must set the PS bit to 0.
The
page code
is the unique code that identifies the page.
Byte 1
The
page length
is the length, in bytes, of the page.
C.1 Read-Write Error Recovery page (01
H
)
The Read-Write Error Recovery page is shown below. This table sum-
marizes the function, the default value and the changeability of each bit.
Bytes
Bits
7 6 543210
0 PS (1) Page code (01
H
)
1 Page length (0A
H
)
2 AWRE ARRE TB RC EER PER DTE DCR
default 0 0 0 0 1000
changeable 1 1 1 1 1111
3 (default) Read retry count (20
H
)
changeable FF
H
4 (default) Correction span (40
H
)
changeable 00
H
5 (default) Head offset count (00
H
)
changeable 00
H
6 (default) Data strobe offset count (00
H
)
changeable 00
H
98 Medalist Pro 2160N/2160WC Product Manual, Rev. A