Product manual

B.3 Additional sense code and additional sense code
qualifier
The additional sense code and additional sense code qualifiers returned
in byte 12 and byte 13, respectively, of the Sense Data Format of the
Request Sense command are listed in the following table.
Error code (hex)
DescriptionByte 12 Byte 13
00 00 No additional information is supplied.
01 00 There is no index/sector signal.
02 00 There is no seek complete signal.
03 00 A write fault occurred.
04 00 Drive not ready; no additional information
04 01
Drive not ready; in Spinup mode
04 02 Drive not ready; waiting for initialization
04 03 Drive not ready; human intervention required
04 04 Drive not ready; format in process
09 00 Track following error
11 00 An unrecovered read error occurred.
11 01
Read retries exhausted
11 02
Error too long to correct
11 04
Unrecoverable read error; Autoreallocation
failed
14 00 No sector found
15 00 A seek positioning error occurred.
16 00 Data synchronization mark error.
17 01
The data was recovered with retries.
18 00 Data recovered with ECC
18 01 The data was recovered with ECC and retries.
18 02
The data was recovered and ARRE was
performed.
19 00
There is an error in the defect list.
19 01
Defect list not available
94 Medalist Pro 2160N/2160WC Product Manual, Rev. A