Specifications
RN: 5-68
RS3: Software Release Notes for P1 R4.2
Changes to RS3 Manuals
OP: Appendix A (Responding to System Faults)
Description: The following note was added after step 1 on page A-2.
NOTE: The Disk shutdown (DS) command should always be performed before
powering down the console. This will purge the cache and prevent possible loss of
data.
PeerWay Interfaces Changes
Changes to the PeerWay Interfaces (PW) are a result of additional
information concerning:
D
Introduction of the MPC5 Controller Processor with the P1 R3.0
release
D
A change in the field of the Contact Input Block ( CIB) used with
code 0200
The following information describes the changes to this manual.
PW: Chapter 1 (SCI)
PW-1: Section 3 (Message Formats)
Description: The change to Table 1.3.35 on page 1-3-43 is to correct
the binary format for 34—message type 34.
Figure 1.3.35. Read Table Data Reply Message-- --Message Type 34
Binary
Format
ASCII
Format
Field Definition
2d 2d Type
34—message type 34.
Description: Changes to Table 1.3.61 on page 1-3-75 include
information for the MPC5 Controller Processor.