User`s manual

15
ARS-2017E Manual
1.3 Disk1 info : the informaiton of the lower hard drive
Display the lower hard drive’s brand, model, firmware version, IDE speed,
status and capacity.
1.4 Health info : the health status of the system
Display the hard drive temperature, the system temperature, the fan speed
of the trays, and the fan speed of the system.
2.SETUP : the settings of the system configuration
Press or to change the option. Press ENT to choose the setting that you
want to change. Before returning to the main menu, the system will ask if you
want to save the changed setting.
2.1 Mirror Opt. : the RAID configuration
2.1.1 Max SCSI speed : set the highest speed limit of SCSI
Options are ASYNC, 10, 20, 40, 80, 160 MB/s. Default is 160MB/s.
2.1.2 Max IDE speed : set the highest speed limit of IDE
Options are ATA33, ATA66, ATA100, ATA133. Default is ATA133.
2.1.3 Rebuild rate : set data rebuilding rate
Options are Slow, Normal, Fast. Default is Normal.
2.1.4 Auto compare : compare the two hard drives’ contents automatically
This function enables automatic comparison of data after rebuilding.
2.1.5 Read balance : read the two hard drives’ data by turns
This function lets each hard drive’s data be read for one minute in order
to lengthen the hard drive’s life.
2.2 Health Opt. : the setting of the system environment
2.2.1 Fan detect : detect the movement of a fan
This function lets the system produce a warning and show a message
whenever the fan is abnormal. Default is Enable.
2.2.2 Fan autocontrol : control a fan automatically
The system will adjust the speed of a fan automatically according to the
warning temperature. When temperature is low enough, the fan won’t move,
and so the speed will display “OK”.
2.2.3 Warning T(°C/°F) : set the warning temperature
If the system temperature is over the set value, there will be a blinking on