Datasheet
Table Of Contents
- 1.0 Introduction 1
- 2.0 Drive specifications 3
- 2.1 Formatted capacity 8
- 2.2 Default logical geometry 8
- 2.3 Recording and interface technology 8
- 2.4 Physical characteristics 9
- 2.5 Access time 9
- 2.6 Start/stop times 9
- 2.7 Power specifications 10
- 2.8 Environmental specifications 14
- 2.9 Acoustics 16
- 2.10 Electromagnetic immunity 16
- 2.11 Reliability 17
- 2.12 Agency certification 17
- 2.13 Environmental protection 19
- 2.14 Corrosive environment 19
- 3.0 Configuring and mounting the drive 21
- 4.0 Serial ATA (SATA) interface 25
- 5.0 Seagate Technology support services 35
- Figure 1. Serial ATA connectors 22
- Figure 2. Attaching SATA cabling 22
- Figure 3. Mounting dimensions (2.0, 1.5 and 1.0 TB models) 23
- Figure 4. Mounting dimensions (500 GB models) 24
- 1.0 Introduction
- 2.0 Drive specifications
- 2.1 Formatted capacity
- 2.2 Default logical geometry
- 2.3 Recording and interface technology
- 2.4 Physical characteristics
- 2.5 Access time
- 2.6 Start/stop times
- 2.7 Power specifications
- 2.8 Environmental specifications
- 2.9 Acoustics
- 2.10 Electromagnetic immunity
- 2.11 Reliability
- 2.12 Agency certification
- 2.13 Environmental protection
- 2.14 Corrosive environment
- 3.0 Configuring and mounting the drive
- 4.0 Serial ATA (SATA) interface
- 5.0 Seagate Technology support services
- Index

28 Barracuda LP Series SATA Product Manual, Rev. B
Security Erase Prepare F3
H
Security Erase Unit F4
H
Security Freeze F5
H
Security Set Password F1
H
Security Unlock F2
H
Seek 70
H
Set Features EF
H
Set Max Address F9
H
Note: Individual Set Max Address
commands are identified by the value
placed in the Set Max Features regis-
ter as defined to the right.
Address:
Password:
Lock:
Unlock:
Freeze Lock:
00
H
01
H
02
H
03
H
04
H
Set Max Address Extended 37
H
Set Multiple Mode C6
H
Sleep E6
H
S.M.A.R.T. Disable Operations B0
H
/ D9
H
S.M.A.R.T. Enable/Disable Autosave B0
H
/ D2
H
S.M.A.R.T. Enable Operations B0
H
/ D8
H
S.M.A.R.T. Execute Offline B0
H
/ D4
H
S.M.A.R.T. Read Attribute Thresholds B0
H
/ D1
H
S.M.A.R.T. Read Data B0
H
/ D0
H
S.M.A.R.T. Read Log Sector B0
H
/ D5
H
S.M.A.R.T. Return Status B0
H
/ DA
H
S.M.A.R.T. Save Attribute Values B0
H
/ D3
H
S.M.A.R.T. Write Log Sector B0
H
/ D6
H
Standby E2
H
Standby Immediate E0
H
Write Buffer E8
H
Write DMA CA
H
Write DMA Extended 35
H
Write DMA FUA Extended CD
H
Write DMA Without Retries CB
H
Write Log Extended 3F
H
Write Multiple C5
H
Write Multiple Extended 39
H
Write Multiple FUA Extended CE
H
Write Sectors 30
H
Write Sectors Without Retries 31
H
Write Sectors Extended 34
H
Command name Command code (in hex)