Constellation ES.3 SAS Product Manual, Rev. F 29
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power require-
ments should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to
each device.
4. Parameters, other than spindle start, are measured after a 10-minute warm up.
5. No terminator power.
6.3.1 Conducted noise immunity
Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise
values given below are peak-to-peak measurements and apply at the drive power connector.
6.3.2 Power sequencing
The drive does not require power sequencing. The drive protects against inadvertent writing during power-up and down.
+5v = 250 mV pp from 100 Hz to 20 MHz.
+12v = 800 mV pp from 100 Hz to 8 KHz.
450 mV pp from 8 KHz to 20 KHz.
250 mV pp from 20 KHz to 5 MHz.