SCSI Commands Reference Manual, Rev. J 77
www.seagate.com Direct Access Block commands (SPC-5 and SBC-4)
Table 41 FMTPINFO field and PROTECTION FIELDS USAGE field (Sheet 1 of 2)
Device server
indication
Application client
specification
Description
SPT
[a]
PROTECT
[b]
FMTP
INFO
PROTECTION
FIELD USAGE
xxxb 0 00b 000b
The logical unit shall be formatted to type 0 protection
[c]
(see SBC-4) resulting in the
P_TYPE field
[d]
being set to 000b.
xxxb 0 00b >000b
Illegal
[e]
xxxb 0 01b xxxb
Illegal
[f]
xxxb 0 1xb xxxb
Illegal
[f]
xxxb 1 00b 000b
The logical unit shall be formatted to type 0 protection
[c]
(see SBC-4) resulting in the
P_TYPE field
[d]
being set to 000b.
xxxb 1 00b >000b
Illegal
[e]
xxxb 1 0b xxxb
Illegal
[f]
000b
001b
011b
111b
1
10b 000b
The logical unit shall be formatted to type 1 protection
[g]
(see SBC-4) resulting in the
P_TYPE field
[d]
being set to 000b.
000b
001b
011b
111b
1
10b >000b
Illegal
[e]
000b 1
11b xxxb
Illegal
[f]
000b
001b
011b
111b
1
11b 000b
The logical unit shall be formatted to type 2 protection
[g]
(see SBC-4) resulting in the
P_TYPE field
[d]
being set to 001b.
001b
010b
1
11b >000b
Illegal
[e]
011b
100b
1
11b 000b
Illegal
[e]
011b
100b
101b
111b
1
11b 001b
The logical unit shall be formatted to type 3 protection.
[g]
(see SBC-4) resulting in the
P_TYPE field
[d]
being set to 010b.
011b
100b
101b
111b
1 11b >001b
Illegal
[e]
110b 1 1xb xxxb
Reserved