User Manual

SCSI Commands Reference Manual, Rev. J 424
www.seagate.com Parameters for direct access devices
STANDBY_Y bit
1 If the STANDBY_Y bit is set to one, then the standby_y condition timer is enabled.
0 If the STANDBY_Y bit is set to zero, then the device server shall ignore the standby_y condition timer.
IDLE_C bit
1 If the IDLE_C bit is set to one, then the idle_c condition timer is enabled.
0 If the IDLE_C bit is set to zero, then the device server shall ignore the idle_c condition timer.
IDLE_B bit
1 If the IDLE_B bit is set to one, then the idle_b condition timer is enabled.
0 If the IDLE_B bit is set to zero, then the device server shall ignore the idle_b condition timer.
IDLE_A bit
1 If the IDLE_A bit is set to one, then the idle_a condition timer is enabled.
0 If the IDLE_A bit is set to zero, then the device server shall ignore the idle_a condition timer.
STANDBY_Z bit
1 If the STANDBY_Z bit is set to one, then the standby_z condition timer is enabled.
0 If the STANDBY_Z bit is set to zero, then the device server shall ignore the standby_z condition timer.
If any of the power condition enable bits (e.g., the IDLE_C bit or the STANDBY_Y bit) are set to zero and are not changeable (see
3.11.1.2), then the device server does not implement the power condition timer associated with that enable bit (see SPC-5).
IDLE_A CONDITION TIMER field
The IDLE_A CONDITION TIMER field specifies the initial value, in 100 millisecond increments, for the idle_a power condition timer (see SPC-5).
This value may be rounded up or down to the nearest implemented time as described in
2.3.
STANDBY_Z CONDITION TIMER field
The STANDBY_Z CONDITION TIMER TIMER field specifies the initial value, in 100 millisecond increments, for the standby_z power condition
timer (see SPC-5). This value may be rounded up or down to the nearest implemented time as described in 2.3.
IDLE_B CONDITION TIMER field
The IDLE_B CONDITION TIMER field specifies the initial value, in 100 millisecond increments, for the idle_b power condition timer (see SPC-5).
This value may be rounded up or down to the nearest implemented time as described in
2.3.
IDLE_C CONDITION TIMER field
The IDLE_C CONDITION TIMER field specifies the initial value, in 100 millisecond increments, for the idle_c power condition timer (see SPC-5).
This value may be rounded up or down to the nearest implemented time as described in
2.3.
STANDBY_Y CONDITION TIMER field
The STANDBY_Y CONDITION TIMER field specifies the initial value, in 100 millisecond increments, for the standby_y power condition timer (see
SPC-5). This value may be rounded up or down to the nearest implemented time as described in 2.3.