PAGE LENGTH field
The PAGE LENGTH field contains the length in bytes of the diagnostic parameters that follow this field. If the application client sends a SEND
DIAGNOSTIC command with a parameter list containing a PAGE LENGTH field that results in the truncation of any parameter, then the com-
mand shall be terminated with CHECK CONDITION status, with the sense key set to ILLEGAL REQUEST, and the additional sense code set to
INVALID FIELD IN PARAMETER LIST.
The diagnostic parameters are defined for each diagnostic page code. The diagnostic parameters within a diagnostic page may be defined dif-
ferently in a SEND DIAGNOSTIC command than in a RECEIVE DIAGNOSTIC RESULTS command.
Table 255 Diagnostic page codes
Page Code Diagnostic Page Name Reference
00h
Supported Diagnostic Pages
5.1.2
01h - 2Fh
Defined by SES-3 for:
a Enclosure services devices (i.e., SCSI devices with the PERIPHERAL DEVICE TYPE
field set to 0Dh in standard INQUIRY data); and
b SCSI devices with the ENCSERV bit set to one in standard INQUIRY data (see
3.6.2).
NOTE These pages are described in SES-3 these
pages are passed along to any attached
enclosure services device.
5.1.5
30h - 3Eh
Reserved
3Fh
See specific SCSI transport protocol for definition
SPC-5
40h
Translate Address Input diagnostic page
5.1.3
Translate Address Output diagnostic page
5.1.4
41h
Obsolete
42h
Rebuild Assist Input diagnostic page
5.1.6
Rebuild Assist Output diagnostic page
5.1.7
43h - 7Fh
See specific device type for definition
80h - FFh
Vendor specific