User Manual
Table Of Contents
- Enterprise Capacity 3.5 HDD
- Seagate® Technology Support Services
- 1.0 Introduction
- 2.0 Drive specifications
- 2.1 Specification summary tables
- 2.2 Formatted capacity
- 2.3 Recording and interface technology
- 2.4 Start/stop times
- 2.5 Power specifications
- 2.6 Environmental limits
- 2.7 Acoustics
- 2.8 Test for Prominent Discrete Tones (PDTs)
- 2.9 Electromagnetic immunity
- 2.10 Reliability
- 2.11 Agency and Safety Certifications
- 2.12 Environmental protection
- 2.14 Corrosive environment
- 2.14 Reference documents
- 2.15 Product warranty
- 3.0 Configuring and mounting the drive
- 4.0 About self-encrypting drives
- 4.1 Data encryption
- 4.2 Controlled access
- 4.3 Random number generator (RNG)
- 4.4 Drive locking
- 4.5 Data bands
- 4.6 Cryptographic erase
- 4.7 Authenticated firmware download
- 4.8 Power requirements
- 4.9 Supported commands
- 4.10 RevertSP
- 4.11 ATA Security Erase Unit Command on SED SATA drives
- 4.12 Sanitize Device - CRYPTO SCRAMBLE EXT
- 5.0 About FIPS
- 6.0 Serial ATA (SATA) interface

Seagate Enterprise Capacity 3.5 HDD v5 Serial ATA Product Manual, Rev. E 10
2.5 Power specifications
The drive receives DC power (+5V or +12V) through a native SATA power connector. See Figure 5 on page 26.
2.5.1 Power consumption
Power requirements for the drives are listed in Table 2 through Table 4. Typical power measurements are based on an average of
drives tested, under nominal conditions, using 5.0V and 12.0V input voltage at 25°C ambient temperature.
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
Table 2 DC power requirements (6TB)
6.0Gb mode
Voltage +5V +12V Watts
Regulation ± 5% Total
Avg Idle Current * 0.190 0.443 6.26
Advanced Idle Current *
Idle_A 0.191 0.438 6.21
Idle_B 0.126 0.384 5.23
Idle_C 0.135 0.228 3.41
Standby 0.117 -0.003 0.55
Maximum Start Current
DC (peak DC) 0.480 1.992
AC (Peak DC) 0.848 2.660
Delayed Motor Start (DC max) 0.220 0.740 9.98
Peak operating current (random read):
Typical DC 0.223 0.798 10.69
Maximum DC 0.230 0.811 10.88
Peak operating current (random write)
Typical DC 0.258 0.512 7.43
Maximum DC 0.263 0.520 7.55
Peak operating current (sequential read)
Typical DC 0.490 0.474 8.13
Maximum DC 0.493 0.479 8.21
Peak operating current (sequential write)
Typical DC 0.428 0.499 8.12
Maximum DC 0.437 0.510 8.30