Complete Window Installation
1. Insert foam seal behind the top of the lower
window sash and against the glass of the
upper window.
2. Place window-lock bracket on top of lower
window and against upper window sash.
3. Use a 3/32” drill bit to drill a starter hole
through the hole in the bracket and into the
window sash.
4. Attach window-lock bracket to window sash
with #10 x ¾” round-head screw to secure
window in place.
_______________________________________
Through-the-wall Cabinet Installation
NOTES:
Handle air conditioner gently.
Be sure your air conditioner cabinet does not
fall out of the opening during installation or
removal.
The location where the power cord exits the
air conditioner should be no more than 4 ft
(122cm) from a grounded 3 prong outlet.
Do not block the louvers on the front panel.
Do not block the louvers on the outside of the
air conditioner.
It is the customer’s responsibility and
obligation to have this product installed by a
qualified technician familiar with through-the-
wall room air conditioner installations.
Option 1 – Wood, metal or plastic molding
When you are using wood, metal or plastic
molding, the wood frame should line up with
inside wall as shown.
Option 2 – Plastered wall with no molding
If the plastered wall is to be flush with the cabinet
and no molding is used, the wood frame must be
set ½” (13mm) into the inside wall.
_______________________________________
Install Wood Frame
1. Construct wood frame. See “Location
Requirements” for dimensions.
2. Measure outside width and height of frame to
determine wall opening dimensions.
3. Cut opening through the wall. Remove and
save insulation.
NOTES:
Dimension for depth depends on wall
thickness and type of molding.
Do not block louvers in air conditioner
cabinet.
Use 1” (2.5cm) or thicker lumber for wood
frame.