User`s manual
Table Of Contents
- SEASAVE
- Limited Liability Statement
- Table of Contents
- Section 1: Introduction
- Section 2: Installation & Use
- Section 3: Configure Inputs, Part I - Instrument Configuration (.con file)
- Introduction
- Instrument Configuration
- Viewing, Modifying, or Creating .con File
- SBE 9plus Configuration
- SBE 16 SEACAT C-T Recorder Configuration
- SBE 16plus SEACAT C-T Recorder Configuration
- SBE 19 SEACAT Profiler Configuration
- SBE 19plus SEACAT Profiler Configuration
- SBE 21 Thermosalinograph Configuration
- SBE 25 SEALOGGER Configuration
- SBE 45 MicroTSG Configuration
- SBE 49 FastCAT Configuration
- Section 4: Configure Inputs, Part II - Calibration Coefficients
- Accessing Calibration Coefficients Dialog Boxes
- Calibration Coefficients for Frequency Sensors
- Calibration Coefficients for A/D Count Sensors
- Calibration Coefficients for Voltage Sensors
- Pressure (Strain Gauge) Calibration Coefficients
- Altimeter Calibration Coefficients
- Fluorometer Calibration Coefficients
- Methane Sensor Calibration Coefficients
- OBS/Nephelometer Calibration Coefficients
- Oxidation Reduction Potential (ORP) Calibration Coefficients
- Oxygen Calibration Coefficients
- PAR/Irradiance Calibration Coefficients
- pH Calibration Coefficients
- Pressure/FGP (voltage output) Calibration Coefficients
- Suspended Sediment Calibration Coefficients
- Transmissometer Calibration Coefficients
- User Polynomial (for user-defined sensor) Calibration Coefficients
- Zaps Calibration Coefficients
- Section 5: Configure Inputs, Part III – Serial Ports, Water Sampler, TCP/IP Ports, Miscellaneous, & Pump Control
- Section 6: Configure Outputs
- Section 7: Display - Setting Up SEASAVE Displays
- Section 8: Real-Time Data & Real-Time Control - Real-Time Data Acquisition
- Section 9: Archived Data Displaying Archived Data
- Section 10: Processing Data
- Appendix I: Command Line Operation
- Appendix II: Configure (.con) File Format
- Appendix III: Software Problems
- Appendix IV: Derived Parameter Formulas
- Index

Section 2: Installation and Use
8
SEASAVE Use
SEASAVE Window
To start SEASAVE:
• Double click on seasave.exe
(default location c:/Program Files/Sea-Bird/Seasave-Win32), or
• Left click on Start and follow the path Programs/Sea-Bird/Seasave-Win32
SEASAVE’s main window looks like this:
• Menus - The Menus contain options for setting up the instrument and the
displays, as well as for starting data acquisition.
• Status display–
The Status display provides the following information:
¾ If SEASAVE is acquiring real-time data or playing archived data.
¾ If SEASAVE is storing real-time data to a file; output data file name.
¾ Instrument configuration (.con) file name.
To display or hide the Status, select Status in the Display menu.
Notes:
• When you start SEASAVE, you
may get a message stating that
Windows Firewall has blocked
some features of this program to
protect your computer, if TCP/IP
ports are enabled in the program
setup (.psa) file. Click Unblock to
permanently unblock the TCP/IP
features of SEASAVE.
• SEASAVE can be run from the
command line. See Appendix I:
Command Line Operation.