User`s manual
Table Of Contents
- SEASAVE
- Limited Liability Statement
- Table of Contents
- Section 1: Introduction
- Section 2: Installation & Use
- Section 3: Configure Inputs, Part I - Instrument Configuration (.con file)
- Introduction
- Instrument Configuration
- Viewing, Modifying, or Creating .con File
- SBE 9plus Configuration
- SBE 16 SEACAT C-T Recorder Configuration
- SBE 16plus SEACAT C-T Recorder Configuration
- SBE 19 SEACAT Profiler Configuration
- SBE 19plus SEACAT Profiler Configuration
- SBE 21 Thermosalinograph Configuration
- SBE 25 SEALOGGER Configuration
- SBE 45 MicroTSG Configuration
- SBE 49 FastCAT Configuration
- Section 4: Configure Inputs, Part II - Calibration Coefficients
- Accessing Calibration Coefficients Dialog Boxes
- Calibration Coefficients for Frequency Sensors
- Calibration Coefficients for A/D Count Sensors
- Calibration Coefficients for Voltage Sensors
- Pressure (Strain Gauge) Calibration Coefficients
- Altimeter Calibration Coefficients
- Fluorometer Calibration Coefficients
- Methane Sensor Calibration Coefficients
- OBS/Nephelometer Calibration Coefficients
- Oxidation Reduction Potential (ORP) Calibration Coefficients
- Oxygen Calibration Coefficients
- PAR/Irradiance Calibration Coefficients
- pH Calibration Coefficients
- Pressure/FGP (voltage output) Calibration Coefficients
- Suspended Sediment Calibration Coefficients
- Transmissometer Calibration Coefficients
- User Polynomial (for user-defined sensor) Calibration Coefficients
- Zaps Calibration Coefficients
- Section 5: Configure Inputs, Part III – Serial Ports, Water Sampler, TCP/IP Ports, Miscellaneous, & Pump Control
- Section 6: Configure Outputs
- Section 7: Display - Setting Up SEASAVE Displays
- Section 8: Real-Time Data & Real-Time Control - Real-Time Data Acquisition
- Section 9: Archived Data Displaying Archived Data
- Section 10: Processing Data
- Appendix I: Command Line Operation
- Appendix II: Configure (.con) File Format
- Appendix III: Software Problems
- Appendix IV: Derived Parameter Formulas
- Index

Section 7: Display - Setting Up SEASAVE Displays
72
Fixed Display
A Fixed Display has a vertical list of the selected parameters to the left, and
displays their current values to the right.
To set up a Fixed Display:
• Click Display, and select Add New Fixed Display Window. OR
• Click Display, and select Import Display Settings (.dsa file). OR
• Right click in an existing Fixed Display and click Modify.
The Fixed Display dialog box looks like this:
When done, click OK.
Viewing SEASAVE Fixed Display
Shown below are example one-column and two-column Fixed Displays:
Right click in the display to:
• Modify – change setup; Fixed Display dialog box appears.
• Export Display Settings (.dsa file) – export setup to .dsa file; Save As
dialog box appears.
• Print – print display; printing dialog box appears. Set up the print job as
desired and click OK.
Time between each calculation of variables for updating display; each display can have
different update rate. Faster than 1 sec can be difficult to view. Set to 0 for full rate data.
Number of
digits to
display to
right of
decimal
point.
Text color and
background color
behind text.
• Double click in
box to change
for that
variable.
• Double click on
heading to
change for all
variables.
Color dialog box
appears; select
desired color and
click OK.
Double click in list
to select variable
for each row.
Number of columns
of data to display
Adjust column width by placing mouse cursor over line at number column header and dragging.