User`s manual
Table Of Contents
- SEASAVE
- Limited Liability Statement
- Table of Contents
- Section 1: Introduction
- Section 2: Installation & Use
- Section 3: Configure Inputs, Part I - Instrument Configuration (.con file)
- Introduction
- Instrument Configuration
- Viewing, Modifying, or Creating .con File
- SBE 9plus Configuration
- SBE 16 SEACAT C-T Recorder Configuration
- SBE 16plus SEACAT C-T Recorder Configuration
- SBE 19 SEACAT Profiler Configuration
- SBE 19plus SEACAT Profiler Configuration
- SBE 21 Thermosalinograph Configuration
- SBE 25 SEALOGGER Configuration
- SBE 45 MicroTSG Configuration
- SBE 49 FastCAT Configuration
- Section 4: Configure Inputs, Part II - Calibration Coefficients
- Accessing Calibration Coefficients Dialog Boxes
- Calibration Coefficients for Frequency Sensors
- Calibration Coefficients for A/D Count Sensors
- Calibration Coefficients for Voltage Sensors
- Pressure (Strain Gauge) Calibration Coefficients
- Altimeter Calibration Coefficients
- Fluorometer Calibration Coefficients
- Methane Sensor Calibration Coefficients
- OBS/Nephelometer Calibration Coefficients
- Oxidation Reduction Potential (ORP) Calibration Coefficients
- Oxygen Calibration Coefficients
- PAR/Irradiance Calibration Coefficients
- pH Calibration Coefficients
- Pressure/FGP (voltage output) Calibration Coefficients
- Suspended Sediment Calibration Coefficients
- Transmissometer Calibration Coefficients
- User Polynomial (for user-defined sensor) Calibration Coefficients
- Zaps Calibration Coefficients
- Section 5: Configure Inputs, Part III – Serial Ports, Water Sampler, TCP/IP Ports, Miscellaneous, & Pump Control
- Section 6: Configure Outputs
- Section 7: Display - Setting Up SEASAVE Displays
- Section 8: Real-Time Data & Real-Time Control - Real-Time Data Acquisition
- Section 9: Archived Data Displaying Archived Data
- Section 10: Processing Data
- Appendix I: Command Line Operation
- Appendix II: Configure (.con) File Format
- Appendix III: Software Problems
- Appendix IV: Derived Parameter Formulas
- Index

Section 3: Configure Inputs, Part I - Instrument Configuration (.con file)
17
Viewing, Modifying, or Creating .con File
1. To create a new .con file: Click Configure Inputs. In the Configure
Inputs dialog box, click the Instrument Configuration tab. Click Create. In
the Select an Instrument dialog box, select the desired instrument and
click OK. Go to Step 3.
2. To select and view or modify an existing .con file: Click Configure
Inputs. In the Configure Inputs dialog box, click the Instrument
Configuration tab. Click Open. In the Select Instrument Configuration
File dialog box, browse to the desired file and click Open. The
configuration information appears on the Instrument Configuration tab.
An example is shown for the SBE 9plus.
Click Modify to bring up a dialog box to change the configuration and/or
view calibration coefficients.
3. The Configuration dialog box appears. Selections at the top are different
for each instrument. An example is shown for the SBE 9plus.
This screen
provides an
easy way to
view
configuration,
but selections
cannot be
modified here;
click Modify to
change
configuration
and/or to view
calibration
coefficients.