Operating instructions

Installation Instructions for the
ME Sr. III Alarm System
SK-210ME (Key Unit)
SK-210KME (Keypad Unit)
SK-295
AC/DC Power Supply
SKP-416K
Special Allen Key
SK-107ME
6 Port ME Splitter
SK-206ME
6 Port ME Strip Module
SK-212ME
12 Port ME Strip Module
Operation Guide
The ME Senior III Alarm Module is designed
to handle up to 12 terminals, (6 or 12 port
strips and 6 port splitter boxes in any combina-
tion), protecting up to 144 items. New micro-
processor technology enables the system to
identify the number of alarm sensors connected
to it, monitor battery level, and perform a con-
tinuous series of system-wide tests that look for
changes resulting from possible tampering.
Lighted LED Bar Graphs visually depict the
condition of batteries and AC power. When an
alarm occurs, it shows precisely which sensor
on which terminal caused the alarm.
The ME Alarm System utilizes the Se-Kure
Controls complete line of “LE” sensors.
Terminals:
Reading Time: 8 Minutes
SK-210KME
ME Sr. Keypad Alarm Module
Page 1
Install the AC/DC Adapter:
1. Plug the SK-295 AC/DC Adapter* into the
power supply jack on the back side of the alarm
module as shown in Fig. 1 at right.
Note: Always use a Se-Kure Controls (SK-295)
AC/DC Power Supply with Se-Kure alarms.
(Using a universal adapter could damage the
system and would void the warranty).
2. Plug the other end of the adapter into any
standard 110v wall outlet.
*International Users May Require a Special Adapter for 220v, (not supplied).
Fig.
1
SK-295
AC/DC Power Supply
Terminal Connection
(from ME Strip Alarm or ME Splitter Box)