Owner's manual
WIRING DETAILS & FUNCTIONS (ALL OPTIONS SHOWN)
ROCKER SWITCH SETTINGS
1 REX TIME 1 SECOND 10 SECONDS INTERNAL RELOCK TIME DELAY WHEN USING
REMOTE REX CONTROLS
2 POWER-UP OPTION ** DISABLED ** ENABLED MANUAL RESET ON POWER-UP REQUIRED WHEN
DISABLED & AUTO RESET ON POWER-UP WHEN ENABLED**
3 REMOTE TRIGGER DISABLED ENABLED ENABLES REMOTE TRIGGER FOR EXTERNAL
ACTIVATION OF DELAYED EGRESS ALARM
4 MASTER / SLAVE MASTER SLAVE DESIGNATES LOCK AS MASTER OR SLAVE FOR
TANDEM APPLICATION – CABLE REQUIRED
** auto reset not available on some versions
SWITCH # DESCRIPTION
ON
OFF
FUNCTION
WIRING & CABLE CONNECTIONS
P:\INSTALLATION INST\Delayed Egress\INST-1581S\INST-1581S.vsd REV D7 03-13 Page 8
1
2 3 4
O
F
F
ROCKER DOWN
J1B
J1A
ROCKER SWITCHES
TRIGGER SENSOR
LOCK COIL CONNECTOR
TANDEM CABLE (OPTIONAL)
J1B CONNECTOR
J1A CONNECTOR
MASTER/SLAVE
CONNECTOR
TO MASTER/SLAVE
CONNECTOR ON
SECOND 1581S
GREEN
BROWN
ORANGE
YELLOW
BLACK
RED
BLUE
WHITE
DPS OUT
DPS CONNECTOR
CONNECTOR INPUT / OUTPUT
GREEN REMOTE TRIGGER INPUT MOM GROUND TO (-) POWER USING DRY CONTACT
BROWN RELAY – COMMON OUTPUT
ORANGE RELAY – N/C WHEN IN ALARM OUTPUT
YELLOW RELAY – N/O WHEN SECURE OUTPUT
BLACK POWER (-) INPUT REGULATED 12/24 VDC (-) POWER
RED POWER (+) INPUT REGULATED 12/24 VDC (+) POWER
BLUE RESET INPUT MOM GROUND TO (-) POWER - DRY CONTACT
WHITE REQUEST TO EXIT (REX) & CONT. BYPASS INPUT (REX) MOM GROUND TO (-) POWER - DRY CONTACT
(CONT. BYPASS) AA GROUND TO (-) POWER – DRY CONTACT
RED
GREEN
WHITE
BLACK
SPDT DRY CONTACT OUTPUT TO REMOTE
CONTROL ANNUNCIATOR, LED OR ALARM SYSTEM
MONITOR – RATING: 1 Amp @ 30 VOLTS RESISTIVE
DESCRIPTIONCONTROL / FUNCTION
J1B
CONNECTOR
J1A
CONNECTOR
WIRE
M/SL
CONNECTOR
CABLE FOR TANDEM LOCK
CONNECTION
(OPTIONAL)
INTERCONNECT
INTERCONNECT CABLE INTERFACING TWO
1581S UNITS (MASTER & SLAVE) FOR PAIRS
OF DOORS. (CABLE MUST BE ORDERED
SEPARATELY).
DPS OPTION
CONNECTOR
GREEN
WHITE
RED
BLACK
SWITCH – COMMON OUTPUT
SWITCH – N/C OUTPUT
SWITCH – N/O OUTPUT
RATING: .250 mA @ 30 VOLTS RESISTIVE
GREEN
WHITE
RED
BLACK
SPARE
-
DPS SENSOR (OPTIONAL)
DPS OPTION
CABLE
BAS OPTION
INTERNALLY WIRED SENSOR. WILL TRIGGER ALARM IF HOLDING FORCE IS BELOW NORMAL.
MAIN
CABLE
1 2 3 4
O
F
F
RO CKER DOWN
ROCKER SWITCH DETAIL
ON
OFF
SHOWN SWITCHED TO
OFF CONDITION