Technical information

25
4 Functions during the dive with microbubble levels
UWATEC
®
Smart dive computers
English
IV
The attention message "Level stop ignored" is
activated if the requested level stop is not observed.
An attention beep* goes off, the arrow
LEVELSTOP
,
the depth and duration of the ignored level stop
begin flashing.
To complete the dive without being reduced to a
lower MB level, you must descend to the prescribed
depth immediately!
The warning "Microbubble level reduced" is
activated if the diver ascends more than 1.5m (5ft)
above the required level stop. Smart then reduces
the MB level, an attention beep* goes off and the
new MB level will flash until the end of the dive. The
level stop for the reduced MB level is now displayed.
To complete the dive without being further reduced
to an even
lower
MB level the new level stop must
be observed.
* Attention beeps can be suppressed via SmartTRAK.
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
m
LEVELSTOP
%
C
4 sec
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
m
LEVELSTOP
%
%
C
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
m
DECO
LEVELSTOP
%
%
C
4 sec
4.2
Total time of ascent
Smart displays the level stop information and the total time of ascent. This
includes the time of ascent as well as all level stops.
The total time of ascent is calculated on the basis of the prescribed
ascent rate and a normal workload. Total time of ascent can be
subject to change if the ascent rate is not ideal (100%) or if Smart
COM detects a higher workload.
4.3 Decompression obligation
Smart calculates and displays level stops to reduce microbubble formation,
but it also calculates the diver's decompression data. If decompression stops
become obligatory, the
DECO
symbol will be displayed. The total ascent time will
now also contain a decompression stop.
You are close to entering decompression:
At the beginning of a decompression phase an
attention beep goes off and the
DECO
symbol
flashes for 8 seconds.
In order to prevent a dive with long decompression
stops it is recommended that you ascend a few
metres/feet on seeing this message.
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
m
DECO
%
%
C
LEVELSTOP
Level stop ignored
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
h
m
LEVELSTOP
%
%
C
4 sec
Microbubble level reduced
Total ascent time
Decompression obligation
Level stop information
WARNING
WARNING
WARNING
New microbubble level