Neutralization (Discharge) Times
All data was taken with the fan speed set to high. All time measurements are in seconds.
NOTE: Discharge times in seconds are representative only and are not a guarantee. Discharge times are actual
measurements recorded in a factory ambient environment.
Per ANSI/ESD S20.20, the test method for Product Qualification test is ANSI/ESD STM3.1, and for Compliance
Verification is ESD TR53 which advises “Measurements should be made at the location where ESD sensitive items
are to be ionized.” A larger area may require additional ionizers. Per S20.20 the required limit for ionizer discharge
time is user defined. Use Table to determine the number of ionizers to achieve ionization of area to be neutralized
to meet your company’s ESD control plan specified discharge times.
The comparative efficiency of bench top ionizers is determined by a standard test published by the ESD
Association: ANSI/ESD STM3.1. Typical positive and negative decay times (±1000V to ±100V) measured using this
standard are shown in Figure 3. The performance of the ionizer was measured with the unit positioned as shown,
with the fan speed on high and without a filter.
TP1 +174.9
-159.6
12" 12"
12"
12"
TP4 +34.7
-34.3
TP7 +24.2
-22.9
TP2 +1.1
-1.2
TP5 +3.2
-3.5
TP8 +6.6
-7.5
TP3 +53.2
-55.3
TP6 +8.5
-10.0
TP9 +7.4
-9.4
963E Benchtop
Air Ionizer
Air Flow
Charged Plate
12"
Figure 3. Neutralization (Discharge) Times
12"
TP10 +30.5
-35.7
TP11 +10.6
-11.1
TP12 +11.0
-12.7