SDS
LIGHTERS
Section 7. Handling and storage
Advice on general
occupational hygiene
Conditions for safe storage,
including any
incompatibilities
No smoking.
Store in accordance with local regulations. Store in a segregated and approved area.
Store away from direct sunlight in a dry, cool and well-ventilated area, away from
incompatible materials (see Section 10). Eliminate all ignition sources. Keep
container tightly closed and sealed until ready for use.
:
:
Protective measures
Contains gas under pressure. Store in cool, ventilated area. Store away from heat,
sparks, open flame, direct sunlight and temperatures exceeding 120°F (49°C). Do not
puncture or incinerate container.
:
Precautions for safe handling
Section 8. Exposure controls/personal protection
Hand protection
Not required under normal conditions of use.
Not required under normal conditions of use.
Eye/face protection
:
:
Body protection
Not required under normal conditions of use.
:
Environmental exposure
controls
:
Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation.
Appropriate engineering
controls
:
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation
or other engineering controls to keep worker exposure to airborne contaminants below
any recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.
Wash hands, forearms and face thoroughly after handling chemical products, before
eating, smoking and using the lavatory and at the end of the working period. Wash
contaminated clothing before reusing. Ensure that eyewash stations and safety
showers are close to the workstation location.
Hygiene measures
:
Control parameters
Individual protection measures
Occupational exposure limits
Skin protection
None.
Canada
Occupational exposure limits
Ingredient
List name
ppm
mg/m³
Other
ppm
mg/m³
Other
ppm
mg/m³
Other
Notations
Butane
US ACGIH 3/2012
1000
-
-
-
-
-
-
-
-
AB 4/2009
1000
-
-
-
-
-
-
-
-
BC 4/2012
600
-
-
750
-
-
-
-
-
ON 7/2010
800
-
-
-
-
-
-
-
-
QC 9/2011
800
1900
-
-
-
-
-
-
-
Propane
US ACGIH 3/2012
1000
-
-
-
-
-
-
-
-
AB 4/2009
1000
-
-
-
-
-
-
-
-
BC 4/2012
1000
-
-
-
-
-
-
-
-
ON 1/2013
1000
-
-
-
-
-
-
-
-
QC 12/2012
1000
1800
-
-
-
-
-
-
-
TWA (8 hours)
STEL (15 mins)
Ceiling
United States
5/10
Calico Brands, Inc.