Instruction Manual

55
Information requirements for electric local space heaters
Model identier(s): KPT-2000B 4507L
Item Symbol Value Unit Item Unit
Heat output
Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat
output
P
nom
2.0 kW Manual heat charge control, with integrated
thermostat
No
Minimum
heat output
(indicative)
P
min
1.0 kW Manual heat charge control with room and/or
outdoor temperature feedback
No
Maximum
continuous
heat output
P
max,c
2.0 kW Electronic heat charge control with room and/or
outdoor temperature feedback
No
Auxiliary electricity consumption
Fan assisted heat output No
Type of heat output/room temperature control
(select one)
At nominal
heat output
el
max
0 kW Single stage heat output and no room
temperature control
No
At minimum
heat output
el
min
0 kW Two or more manual stages, no room
temperature control
No
In standby
mode
el
SB
0,000 kW With mechanic thermostat room temperature
control
No
With electronic room temperature control No
Electronic room temperature control plus day
timer
No
Electronic room temperature control plus week
timer
Yes
Other control options (multiple selections possible)
Room temperature control, with presence
detection
No
Room temperature control, with open window
detection
Yes
With distance control option No
With adaptive start control No
With working time limitation Yes
With black bulb sensor No
Contact details Kingsher International Products B.V., Rapenburgerstraat 175E
1011 VM Amsterdam, The Netherlands
Kingsher International Products Limited, 3 Sheldon Square. London
W2 6PX United Kingdom