User's Manual

Screen Service SDT ARK 1 ECHO Operations
Jan, 2012 v 1.ATSC_FCC Page 3 - 119
OID
Name
R\W
Description
1.3.6.1.4.1.21678.183.7
echo_HW_monitor
OBJ ID
1.3.6.1.4.1.21678.183.7.1
echo_HW_monitor_RflPowerDbm
R
Reflex power [dBm x 10]
1.3.6.1.4.1.21678.183.7.2
echo_HW_monitor_Amplifier
R
Amplifier status 0: on 1: off 2: restart 3: stand by off 4: GPS off 5: init
6: alarm off 7: rf off 8: opto off 9: change mode
1.3.6.1.4.1.21678.183.7.3
echo_HW_monitor_CurrentOut
R
Current indicator (mA)
1.3.6.1.4.1.21678.183.7.4
echo_HW_monitor_PowerSupply
R
Voltage indicator (mV): 28V for 20W and 50W versions, and 42V for 200W
version"
1.3.6.1.4.1.21678.183.7.5
echo_HW_monitor_FanPulse
OBJ ID
1.3.6.1.4.1.21678.183.7.5.1
echo_FanSpeed1
R
FAN 1 speed (rpm)
1.3.6.1.4.1.21678.183.7.5.2
echo_FanSpeed2
R
FAN 2 speed (rpm)
1.3.6.1.4.1.21678.183.7.5.3
echo_FanSpeed3
R
FAN 3 speed (rpm) - only for 200W version
1.3.6.1.4.1.21678.183.7.5.4
echo_FanSpeed4
R
FAN 4 speed (rpm) - only for 200W version
1.3.6.1.4.1.21678.183.7.6
echo_HW_monitor_Temperature
OBJ ID
1.3.6.1.4.1.21678.183.7.6.1
echo_TemperatureCase
R
Case temperature
1.3.6.1.4.1.21678.183.7.6.2
echo_TemperaturePsu
R
PSU temperature
1.3.6.1.4.1.21678.183.7.6.3
echo_TemperatureCase2
R
Case temperature 2 (only in SDTX 200 version)
1.3.6.1.4.1.21678.183.7.7
echo_HW_monitor_Relays
OBJ ID
1.3.6.1.4.1.21678.183.7.7.1
echo_Relay0Status
R
Relay 0 status 0: on 1: off
1.3.6.1.4.1.21678.183.7.7.2
echo_Relay1Status
R
Relay 1 status 0: on 1: off
1.3.6.1.4.1.21678.183.7.7.3
echo_Relay2Status
R
Relay 2 status 0: on 1: off
1.3.6.1.4.1.21678.183.7.7.4
echo_Relay3Status
R
Relay 3 status 0: on 1: off
1.3.6.1.4.1.21678.183.7.8
echo_HW_monitor_Opto
OBJ ID
1.3.6.1.4.1.21678.183.7.8.1
echo_Opto0Status
R
Opto 0 status (RF Off): if closed the output RF is switch off 0: closed 1: