User's Manual
Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 76
Box
Parameter /
Control
Description Admitted Ranges / Values I/A
Status 28V / 42V
PSU voltage indicator (values are expressed in V). It depends on the hardware type of the device:
• 28V for SDTx_ARK1 20W and 50W;
• 42V for SDTx_ARK1 200W.
I/A
Status
Current PSU
28V / 42V [A]
PSU current indicator (values are expressed in A). I/A
Status 24V
PSU 24V indicator (values are expressed in V).
Only in SDTX 200 version.
I/A
Status
Case
Temperature
Case temperature indicator (values are expressed in °C). I/A
Status
Case
Temperature 2
2
nd
Case temperature indicator (values are expressed in °C).
Only in SDTX 200 version.
I/A
Status
PSU
Temperature
PSU temperature indicator (values are expressed in °C). I/A
Status Fan 1 Fan 1 speed indicator (values are expressed in rpm). I/A
Status Fan 2 Fan 2 speed indicator (values are expressed in rpm). I/A
Status Fan 3
Fan 3 speed indicator (values are expressed in rpm).
Only in SDTX 200 version.
I/A
Status Fan 4
Fan 4 speed indicator (values are expressed in rpm).
Only in SDTX 200 version.
I/A
Status
FWD Power
[dBm]
Output forward power indicator (values are expressed in dBm). I/A