User's Manual

Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 104
Table 19.
Events descriptions list
Event Description Description
RF OFF enabled from OPTO RF output switched off through OPTO 0.
RF OFF disabled from OPTO RF output switched on through OPTO 0.
Stand-by ON from OPTO Stand-by mode enabled through OPTO 3.
Stand-by OFF from OPTO Stand-by mode disabled through OPTO 3.
Stand-by ON from LCD Stand-by mode enabled through LCD button.
Stand-by OFF Stand-by mode disabled through LCD button.
Power = xx.x dBm (source)
New output power setting.
xx.x: output power expressed in dBm.
Source: Local or MIP
Update file *.xxxx
New file loading.
Xxxx: file extension.
P5K open: xx.xx.xx.xx
Connection to port 5000 open.
xx.xx.xx.xx: host IP address.
P5K closed Connection to port 5000 closed.
Mode X= (mode)
Manual change mode.
X: new mode (A/B)
mode: Tx ATSC – Tx ITU 470.
Switch mode swhitch X => Y
Switch mode change.
Switch mode: Manual / Auto / Opto / Time.
X=>Y: A/B=>B/A.
UPCV not configured
The Upconverter has been found not configured during the
UPCV_TASK (refer to
Task Error Event
paragraph).
UPCV configured
Automatic reconfiguring of the Upconverter. It automatically starts at
every UPCV not configured event or UPCV communication error.
File system busy
File system already in use while tring to employ it (e.g. change mode
during a file loading).
UTC Time set from GPS
Time and date set by GPS. As soon as the GPS lock is regained,
once lost, and if the current time and date are different from the GPS
ones, the UTC time is set by GPS.
Warm UP Restart
When Warm up alarm is risen this event is reported and the device is
restarted.