User's Manual
Screen Service SDT 200UB – SDT 500UB ARK-1 ATSC Operations
July, 2009 v 1.0 Page 3 - 98
Signal 129 MHz Lock
• GPS communication error alarm is not signaled
• GPS lock alarm is not signaled
• 10 MHz lock alarm is not signaled
• 129 MHz is not locked.
I/A
• 129 MHz oscillator can loose the lock
• Hardware fault
1
Signal 960 MHz Lock 960 MHz is not locked. I/A
• Hardware fault
1
Down Converter Osc. Unlock
PLL of the Down-converter board not locked to 129 MHz
clock.
A
• Hardware fault
X (0)
ITU Wrong Input Standard
• Device in ITU470 mode
• Selected SDI signal standard is not NTSC
I
• Check input statistics
X (1)
RF Input Squelch
• Device in ATSC mode
• RF input alarm is not signaled.
• RF signal level under the squelch threshold
A
• Check Squelch alarm threshold
• Check input channel
• Check RF input source and signal
X (0)